STANDARD FEATURES |
|
|
|
|
FLOATING ZERO |
|
|
Allows more precise accuracy by compensating for valve closing time. Also can be used to prevent water hammer. |
|
|
|
COMPONENT FAILURE ALARM |
|
|
Visible signal with low-level audible alarm shows failure of almost any component in the system which could ruin the batch. |
|
|
|
ENCLOSURE |
|
|
A 12"x10"x5" JIC enclosure. JIC is equivalent to NEMA 12. |
|
|
|
BATTERY BACKUP |
|
|
A 7.2VDC Ni. Cad. battery retains memory in case of power loss. Charges continuously when power is on. |
|
|
|
FIVE DIGIT LED COUNTER |
|
|
Resets itself automatically on start of each batch. |
|
|
|
SIX DIGIT ELECTROMECHANICAL COUNTER |
|
|
Non-resettable. Runs at one-tenth the speed of the LED counter. |
|
|
|
REMOTE RESET |
|
|
Terminals are available for remote reset and emergency stop switches. |
|
|
|
SPLASH PROOF CONSTRUCTION |
|
|
|
FIVE DIGIT PRESET |
|
|
OPTIONAL FEATURES |
|
|
|
|
SCALER |
|
|
Converts flowmeter pulses into any unit of measurement desired. For higher resolution, incoming pulses are multiplied by a factor of 1, 10, 100 or 1000. can be used with turbine meters or in place of change gears on positive displacement meters. |
|
|
|
PREWARN |
|
|
Pre-warn is used with a two-stage closing valve to prevent water hammer. |
|
|
|
FIBERGLASS ENCLOSURE |
|
|
A NEMA 4 (12"x10"x5") fiberglass enclosure with stainless steel hinges and hardware. |
|
|
|
STAINLESS STEEL ENCLOSURE |
|
|
A NEMA 4 (12"x10"x6") stainless steel enclosure available. |
|
|
|
STAINLESS STEEL PANEL MOUNT |
|
|
12 1/2"x10 1/2" panel with up to 10 feet of ribbon cable to power supply mounted on separate printed circuit board. |
|
|
|
AUDIBLE ALARM |
|
|
Louder audible alarm available for the component failure monitor. |
|
|
|
SELECTOR SWITCH |
|
|
Single pole 10-position rotary switch is available. |
|
|
|
PREAMPLIFIER |
|
|
For turbine meters. |
|
|
|
220 VAC OPERATION |
|
|
GENERAL SPECIFICATIONS |
|
|
|
|
INPUT VOLTAGE |
|
|
105-130 VAC, 50 watts, 50 or 60 Hz. |
|
|
|
PULSE INPUT |
|
|
Reed pulsers, photo electric pulsers, magnetic and proximity sensors (some electronic sensors require pre-amplification). unit requires square wave input count registered at logic "0". |
|
|
|
MAXIMUM COUNT INPUT FREQUENCY |
|
|
10,000 Hz. |
|
|
|
MAXIMUM COUNT OUTPUT FREQUENCY |
|
|
10,000 counts/minute. |
|
|
|
CONTROL OUTPUTS |
|
|
Single stage - 2 DPDT contacts. Two stage - 2 additional DPDT contacts. Contacts are reed at 5 Amp, 120 VAC non-inductive. |
|
|
|
Continued |
|
|